Medical Devices
Issues (1)
Change Request Status = Closed (epsos-issue-318): Modify Datatype of effectiveTime element to represent implant data and removal date
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Events
Tracking / Status = Closed 2021-04-29 11:36:13: Tracking by Mathias Ghys
Description
Implemented as part of CP-050
Tracking / Status = Open 2019-11-07 16:21:43: Tracking by Mathias Ghys
Assignment2019-10-03 14:20:49: Assigned To Mathias Ghys by Mathias Ghys
Tracking / Status = Open 2019-10-03 14:20:48: Tracking by Mathias Ghys
Description
Finding:

At the moment, in the CDA IGs, the effectiveTime element has the datatype TS, with a cardinality of 1 ... * and conformance R. This has to be changed to IVL_TS, with a cardinality of 1 ... 1.

Suggestion:

Suggestion is to take the IPS CDA IG as an inspiration

Further explanation:

- Link to JIRA issue: https://ec.europa.eu/cefdigital/tracker/projects/EHSEMANTIC/issues/EHSEMANTIC-487

 
 