Vital Signs Observation
Issues (7)
Change Request Status = Closed (epsos-issue-113): Missing id in template
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Current Labels
 
 (M1) Milestone 1 
Events
Tracking / Status = Closed 2015-11-25 13:00:10: Tracking by Dr. Kai U. Heitmann
 
 M1 
Description
Element id added as 0..* R
Assignment2015-11-25 12:38:01: Assigned To Dr. Kai U. Heitmann by Dr. Kai U. Heitmann
 
 M1 
Tracking / Status = Open 2015-11-25 12:38:00: Tracking by Dr. Kai U. Heitmann
 
 M1 
Description
Finding:

id: is mandatory in ELGA and other specs; also mentioned in the example but NOT in the template.

Suggestion:

Shall be added at least as O to the template, otherwise specifying an id in an instance checked in a closed template environment would lead to an error

Further explanation:

-

Change Request Status = Closed (epsos-issue-114): Code no value set bound
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Current Labels
 
 (M1) Milestone 1 
Events
Tracking / Status = Closed 2015-11-25 13:01:03: Tracking by Dr. Kai U. Heitmann
 
 M1 
Description
Observation.code now bound to epSOSBloodPressure value set 1.3.6.1.4.1.12559.11.10.1.3.1.42.21
Tracking / Status = Open 2015-11-25 12:38:27: Tracking by Dr. Kai U. Heitmann
 
 M1 
Description
Finding:

code: has no Value Set

Suggestion:

Shall be the epSOS epSOSBloodPressure value set 1.3.6.1.4.1.12559.11.10.1.3.1.42.21 according to the spec

Further explanation:

-

For future consideration Status = Open (epsos-issue-115): More codes in value set
TypeFor future considerationStatusFor future consideration Status = Open PriorityNormal
Current Labels
 
 (M4) Milestone 4 
Events
Tracking / Status = Open 2015-11-25 12:39:27: Tracking by Dr. Kai U. Heitmann
 
 M4 
Description
Finding:

Only a few concepts in associated value set Obs.code

Suggestion:

In the future a value set should contain much more concepts, see e.g. ELGA_Vitalparameterarten 1.2.40.0.34.10.34

Further explanation:

-

Change Request Status = Closed (epsos-issue-116): Add text element
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Current Labels
 
 (M1) Milestone 1 
Events
Tracking / Status = Closed 2015-11-26 15:51:40: Tracking by Dr. Kai U. Heitmann
 
 M1 
Description
Done
Assignment2015-11-25 12:39:55: Assigned To Dr. Kai U. Heitmann by Dr. Kai U. Heitmann
 
 M1 
Tracking / Status = Open 2015-11-25 12:39:54: Tracking by Dr. Kai U. Heitmann
 
 M1 
Description
Finding:

text: is in the example but not in the template

Suggestion:

Shall be added at least as O to the template, otherwise specifying text in an instance checked in a closed template environment would lead to an error

Further explanation:

-

Change Request Status = Closed (epsos-issue-117): statusCode missing
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Current Labels
 
 (M1) Milestone 1 
 
 (TBA) To be approved 
Events
Tracking / Status = Closed 2015-11-26 15:35:19: Tracking by Dr. Kai U. Heitmann
 
 M1 
 
 TBA 
Description
Done
Assignment2015-11-25 12:40:24: Assigned To Dr. Kai U. Heitmann by Dr. Kai U. Heitmann
 
 M1 
 
 TBA 
Tracking / Status = Open 2015-11-25 12:40:23: Tracking by Dr. Kai U. Heitmann
 
 M1 
 
 TBA 
Description
Finding:

statusCode: is in the example (fixed to completed) but not in the template

Suggestion:

Shall be added as M fixed completed to the template.

Further explanation:

-

Change Request Status = Closed (epsos-issue-118): Use of methodCode and targetSiteCode
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Current Labels
 
 (M3) Milestone 3 
Events
Tracking / Status = Closed 2016-03-29 16:51:44: Tracking by Giorgio Cangioli
 
 M3 
Description
Those elements had value sets associated. They were included in the template, but not accepted by functional experts as part of the Patient Summary data set.

Left as optional element without voc bunding only for future consideration. Added a note in the template description.
Assignment2016-03-17 11:34:59: Assigned To Giorgio Cangioli by Dr. Kai U. Heitmann
 
 M3 
Description
leave these elements in the template but check the actual value set binding
Tracking / Status = Open 2015-11-25 12:41:25: Tracking by Dr. Kai U. Heitmann
 
 M3 
 
 TBA 
Description
Finding:

interpretationCode: not used in ELGA

methodCode: has no value set bound to it (like ObservationInterpretation); not used in ELGA

targetSiteCode: has no value set bound to it; not used in ELGA; needs differentiation to methodCode; LOINC would be able to include information about both methodCode and targetSiteCode

Suggestion:

How to deal with it now

Further explanation:

-

Change Request Status = Closed (epsos-issue-263): Add effective time element to Vital Signs Observation
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Current Labels
 
 (TBA) To be approved 
Events
Tracking / Status = Closed 2018-03-28 11:07:56: Tracking by Mathias Ghys
 
 TBA 
Description
Effective type with datatype TS has been added to the Vital Signs Observation template.
Issue is related to issue #266
Assignment2018-02-23 11:11:53: Assigned To Mathias Ghys by Mathias Ghys
 
 TBA 
Tracking / Status = Open 2018-02-23 11:11:52: Tracking by Mathias Ghys
 
 TBA 
Description
Finding:

- The Vital Signs Observation is a specialization of the general Observation template. The general Observation template contains an effectiveTime, so I would expect the Vital Signs Observation template to also contain the effectiveTime element

Suggestion:

- Add effectiveTime element to Vital Signs Observation

Further explanation:

-

 
 