Issues (6)
Change Request Status = Closed (epsos-issue-156): Assert not aligned with the error message
TypeChange RequestStatusChange Request Status = Closed PriorityLow
Current Labels
 
 (M1) Milestone 1 
Events
Tracking / Status = Closed 2019-04-30 14:24:38: Tracking by Mathias Ghys
 
 M1 
Description
Aligned error message with assert.
Tracking / Status = Open 2017-05-17 14:54:30: Tracking by Giorgio Cangioli
 
 M1 
Tracking / Status = Open 2017-04-12 13:09:11: Tracking by Giorgio Cangioli
Description
Finding:

The Assert statement associated with the assignedAuthor seemes not aligned with the error message "If assignedAuthor has an associated representedOrganization with no assignedPerson or assignedAuthoringDevice, then the value for "ClinicalDocument/author/assignedAuthor/id/@nullFlavor" SHALL be "NA" "Not applicable" 2.16.840.1.113883.5.1008 NullFlavor STATIC."


Suggestion:

-

Further explanation:

-

Change Request Status = Closed (epsos-issue-157): Cardinality of the name prefix and suffix
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Current Labels
 
 (M1) Milestone 1 
Events
Tracking / Status = Closed 2017-11-15 17:00:10: Tracking by Mathias Ghys
 
 M1 
Description
This issue is related to issue 161 and the cardinality of the prefix/suffix is changed to 0 ... * (which is compliant with the HL7 CDA specifications)
Assignment2017-07-18 23:23:03: Assigned To Christof Gessner by Christof Gessner
 
 M1 
Tracking / Status = Open 2017-04-12 13:12:15: Tracking by Giorgio Cangioli
 
 M1 
Description
Finding:

There are several hl7:prefix and hl7:suffix that are set to 1..* instead of 0..*-

Suggestion:

Change the cardinality

Further explanation:

-

Change Request Status = Closed (epsos-issue-161): (epSOSCDAauthor): prefix and suffix is required for assignedPerson
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Events
Tracking / Status = Closed 2017-05-17 09:23:23: Tracking by Giorgio Cangioli
Description
Changed the cardinailty for authior and legal auth.
Assignment2017-05-15 22:50:14: Assigned To Christof Gessner by Christof Gessner
Tracking / Status = Open 2017-05-15 22:50:13: Tracking by Christof Gessner
Description
Finding:

- (epSOSCDAauthor): prefix and suffix is required for assignedPerson

Suggestion:

- change cardinality to 0...*

Further explanation:

- probably, behaviour should be the same for all instances of person name.
- same as epsos-issue-157

Change Request Status = Closed (epsos-issue-256): Change Conformance of HCP assignedPerson family and given name according to documentation
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Events
Tracking / Status = Closed 2018-01-10 16:15:35: Tracking by Mathias Ghys
Description
I processed the changes
Assignment2018-01-10 11:57:36: Assigned To Mathias Ghys by Mathias Ghys
Tracking / Status = Open 2018-01-10 11:57:35: Tracking by Mathias Ghys
Description
Finding:

- In the EXPAND documentation, family and given name are set to 'R'.

Suggestion:

- Change conformancy in ART-DECOR from 'R' to 'M'

Further explanation:

-

Change Request Status = Open (epsos-issue-277): Restrict the nullFlavor value for Telecom element in author to "NI"
TypeChange RequestStatusChange Request Status = Open PriorityNormal
Events
Assignment2018-06-21 13:10:10: Assigned To Mathias Ghys by Mathias Ghys
Tracking / Status = Open 2018-06-21 13:10:09: Tracking by Mathias Ghys
Description
Finding:

For reasons of consistency with other telecom elements, restrict the nullFlavor value of the assignedAuthor element to "NI". It is also specified like this in the Expand documentation.

Suggestion:

- Restrict nullFlavor value of assignedAuthor to "NI"

Further explanation:

-

Change Request Status = Closed (epsos-issue-294): Improve description for hl7:assignedAuthor/hl7:id
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Events
Tracking / Status = Closed 2019-04-30 14:28:18: Tracking by Mathias Ghys
Description
Description adapted
Assignment2019-02-14 09:57:25: Assigned To Mathias Ghys by Mathias Ghys
Tracking / Status = Open 2019-02-14 09:57:24: Tracking by Mathias Ghys
Description
Finding:

- We got some questions about this element and noticed the description was not fully clear.

Suggestion:

- Change the description from "HP ID number" to "Identification of the Healthcare Practitioner that is the author of this document"

Further explanation:

-

 
 
Busy