Loading...
Help
Login
Busy
Search
eHDSI - Templates
 
Template locked

OK Not OK
Templates (External repositories)

Warning Ok
Warning
Filter
eHDSI Related Prescription
Issues (1)
Change Request Status = Closed (epsos-issue-327): containment of the general CDA template of a ManufacturedProduct has to be adapted to the epSOS CDA ManufacturedProduct
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Events
Tracking / Status = Closed 2019-12-23 09:18:57: Tracking by Mathias Ghys
Assignment2019-12-23 09:16:56: Assigned To Mathias Ghys by Mathias Ghys
Tracking / Status = Open 2019-12-23 09:16:55: Tracking by Mathias Ghys
Description
Finding:

Here the hl7:consumable element has a containment of the   CDA ManufacturedProduct   template instead of the   epSOS CDA ManufacturedProduct   template.  This is causing an issue in the validation of the eDispensation, since the former has a constraint to a value set, that is not there in our template, resulting in a validation error.


Suggestion:

- Modify the template link

Further explanation:

- Link to related JIRA issue: https://ec.europa.eu/cefdigital/tracker/browse/EHSEMANTIC-505

 
 