Back To Index  <<  Back To Templates

retired Template  eHDSI Vital Signs Observation

Id 1.3.6.1.4.1.12559.11.10.1.3.1.3.22 Effective Date 2020‑09‑03 15:17:32
Other versions this id:
Status retired Retired Version Label
Name eHDSIVitalSignsObservation Display Name eHDSI Vital Signs Observation
Description

A vital signs observation is a simple observation that uses a specific vocabulary, and inherits constraints from CCD.

Note: Although interpretationCode, methodCode and targetSiteCode are foreseen by the parent template, and initially introduced also in the eHDSI template, they are not supposed to be actually used in this version since they were not included in the functional specifications and therefore not validated from a functional point of view. Those element have been retained as optional elements, without vocabulary binding defined, only for future consideration.  


Context Parent nodes of template element with id 1.3.6.1.4.1.12559.11.10.1.3.1.3.22
Classification CDA Entry Level Template
Open/Closed Open (other than defined elements are allowed)
Relationship Specialization: template 1.3.6.1.4.1.12559.11.10.1.3.1.3.20 eHDSI Simple Observation (DYNAMIC)
Example
Example
<observation classCode="OBS" moodCode="EVN">
  <templateId root="1.3.6.1.4.1.12559.11.10.1.3.1.3.22"/>  <templateId root="1.3.6.1.4.1.12559.11.10.1.3.1.3.20"/>  <templateId root="1.3.6.1.4.1.19376.1.5.3.1.4.13"/>  <templateId root="1.3.6.1.4.1.19376.1.5.3.1.4.13.2"/>  <templateId root="2.16.840.1.113883.10.20.1.31"/>  <id root=" " extension=" "/>  <code code=" " codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC"/>  <text>
    <reference value="#xxx"/>  </text>
  <statusCode code="completed"/>  <effectiveTime value=" "/>  <repeatNumber value=" "/>  <value type="PQ" value=" " unit=" "/>  <interpretationCode code=" " codeSystem=" " codeSystemName=" "/>  <methodCode code=" " codeSystem=" " codeSystemName=" "/>  <targetSiteCode code=" " codeSystem=" " codeSystemName=" "/></observation>
Item DT Card Conf Description Label
hl7:observation
1 … 1 R (eHDdotsion)
hl7:templateId
II.EPSOS 1 … 1 M eHDSI Vital Signs Observation (eHDdotsion)
@root
uid 1 … 1 F 1.3.6.1.4.1.12559.11.10.1.3.1.3.22
hl7:templateId
II.EPSOS 1 … 1 M eHDSI Simple Observation (eHDdotsion)
@root
uid 1 … 1 F 1.3.6.1.4.1.12559.11.10.1.3.1.3.20
hl7:templateId
II.EPSOS 1 … 1 M IHE Simple Observation (IHE PCC) (eHDdotsion)
@root
uid 1 … 1 F 1.3.6.1.4.1.19376.1.5.3.1.4.13
hl7:templateId
II.EPSOS 1 … 1 M IHE Vital Signs Observation (IHE PCC) (eHDdotsion)
@root
uid 1 … 1 F 1.3.6.1.4.1.19376.1.5.3.1.4.13.2
hl7:templateId
II.EPSOS 1 … 1 M Result observation (CCD) (eHDdotsion)
@root
uid 1 … 1 F 2.16.840.1.113883.10.20.1.31
hl7:id
II 1 … * M (eHDdotsion)
hl7:code
CE.EPSOS 1 … 1 M

A vital signs observation entry shall use one of the following LOINC codes, with the specified data types and units.

LOINC Display Name Unit Datatype
8480-6 INTRAVASCULAR SYSTOLIC mm[Hg] PQ
8462-4 INTRAVASCULAR DIASTOLIC mm[Hg] PQ

(eHDdotsion)
  CONF
The value of @code shall be drawn from value set 1.3.6.1.4.1.12559.11.10.1.3.1.42.21 eHDSIBloodPressure (DYNAMIC)
hl7:text
ED 1 … 1 M (eHDdotsion)
hl7:reference
TEL 1 … 1 M (eHDdotsion)
@value
1 … 1 R Reference pointing to the narrative, typically #{label}-{generated-id}, e.g. #xxx-1
hl7:statusCode
CS 1 … 1 M (eHDdotsion)
@code
CONF 1 … 1 F completed
hl7:effectiveTime
TS 1 … 1 R Date when the measurement was done.
This date shall be the same as the effective time for the Vital Signs organizer element.
(eHDdotsion)
  Example <effectiveTime value="20180327"/>
hl7:value
PQ 1 … 1 R

The <value> element shall be present, and shall be of the appropriate data type specified for measure in the table above.

(eHDdotsion)
  CONF
@unit is "mm[Hg]"
hl7:interpretationCode
CE 0 … * R

The interpretation code may be present to provide an interpretation of the vital signs measure (e.g., High, Normal, Low, et cetera).

Not expected to be used in this version of the Patient Summary, retained as optional elements, without vocabulary binding defined, only for future consideration.

(eHDdotsion)
hl7:methodCode
CE 0 … * R

The <methodCode> element may be present to indicate the method used to obtain the measure. Note that method used is distinct from, but possibly related to the target site.

Not expected to be used in this version of the Patient Summary, retained as optional elements, without vocabulary binding defined, only for future consideration.

(eHDdotsion)
hl7:targetSiteCode
CD 0 … * R

The target site of the measure may be identified in the <targetSiteCode> element (e.g., Left arm [blood pressure], oral [temperature], et cetera).

Not expected to be used in this version of the Patient Summary, retained as optional elements, without vocabulary binding defined, only for future consideration.

(eHDdotsion)