hl7:supply
|
|
|
R |
The <supply> element shall be present. The moodCode attribute shall be EVN to reflect
that a medical device has been provided.
|
(eHD ice) |
@classCode
|
cs |
1 … 1 |
F |
SPLY |
@moodCode
|
cs |
1 … 1 |
F |
EVN |
hl7:templateId
|
II |
1 … 1 |
R |
eHDSI Medical Device |
(eHD ice) |
@root
|
uid |
1 … 1 |
F |
1.3.6.1.4.1.12559.11.10.1.3.1.3.5 |
hl7:id
|
II |
0 … * |
R |
This optional element identifies the provision of the device.
|
(eHD ice) |
hl7:code
|
CD |
0 … 1 |
R |
|
(eHD ice) |
hl7:text
|
ED |
0 … 1 |
R |
The <text> element references the part of the section narrative, which contains the
description of the device.
|
(eHD ice) |
|
|
hl7:reference
|
TEL |
1 … 1 |
M |
|
(eHD ice) |
@value
|
|
1 … 1 |
R |
Reference pointing to the narrative, typically #{label}-{generated-id}, e.g. #xxx-1 |
hl7:effectiveTime
|
IVL_TS |
1 … 1 |
R |
This element provides the interval of time corresponding to the device usage by/presence
in the patient. If only the value attribute is specified without the low/high sub elements, it is
considered the implant date of the device.
|
(eHD ice) |
|
|
@xsi:type
|
|
1 … 1 |
F |
IVL_TS |
|
Example |
A medical device still present in the patient <effectiveTime xsi:type="20070728"> <low value="20070728"/></effectiveTime> |
|
Example |
A medical device that has been removed from the patient <effectiveTime xsi:type="IVL_TS"> <low value="20070728"/> <high value="20150215"/></effectiveTime> |
|
Example |
A medical device still present in the patient <effectiveTime value="20070728" xsi:type="IVL_TS"/> |
hl7:low
|
|
1 … 1 |
R |
The lower bound of the interval represents the start date/time. |
(eHD ice) |
|
|
hl7:high
|
|
0 … 1 |
C |
The upper bound represents the end date/time. If it is not present, the device is
still used by or present in the patient.
|
(eHD ice) |
|
|
hl7:participant
|
|
1 … * |
R |
The device is represented as a participant in the supply structure. The following
descriptions apply to the device structure.
|
(eHD ice) |
@typeCode
|
cs |
1 … 1 |
F |
DEV |
|
Example |
<participant typeCode="DEV"> <participantRole classCode="MANU"> <id root=""/> <playingDevice classCode="DEV" determinerCode="INSTANCE"> <code code="" codeSystem=""/> <!-- ... --> </playingDevice> </participantRole></participant> |
hl7:participantRole
|
|
1 … 1 |
R |
|
(eHD ice) |
@classCode
|
cs |
1 … 1 |
F |
MANU |
hl7:id
|
|
0 … * |
R |
The device ID is represented by the <id> element of the participant role. This element
is optional, as not all device identifiers (serial numbers) may be known to the provider
or patient.
|
(eHD ice) |
|
|
hl7:playingDevice
|
|
1 … 1 |
R |
The <playingDevice> element describes the device instance. The class code shall contain
the value of "DEV", and the determiner code shall contain "INSTANCE".
|
(eHD ice) |
@classCode
|
cs |
1 … 1 |
F |
DEV |
@determinerCode
|
cs |
1 … 1 |
F |
INSTANCE |
hl7:code
|
|
1 … 1 |
R |
The device code describes the type of device (e.g. arm prosthesis, arterial stent).
It shall contain codes from the eHDSIMedicalDevice value set OID 1.3.6.1.4.1.12559.11.10.1.3.1.42.8.
One of the concepts from the Value Set eHDSIAbsentOrUnknownDevice shall be used in
the <code> element to record that:
- There is no information available regarding implanted or external devices for the
subject.
- There are no devices known to be implanted in or used by the subject that have to
be reported in this record. This can mean either that there are none known, or that
those known are not relevant for the purpose of this record.
|
(eHD ice) |
|
|
|
CONF |
|