Help
Login
Busy
Search
eHDSI - Templates

 
Template locked

OK Not OK
Templates (External repositories)

Warning Ok
Warning
Filter
true50
epSOS CDA substanceAdministration
false
Issues (2)
false
Change Request Status = Closed ( epsos-issue-321 ): Adapt description of hl7:id element
Type Change Request Status Change Request Status = Closed Priority Normal
Events
Tracking / Status = Closed 2019-11-12 12:11:49 : Tracking by Mathias Ghys
Description
Nothing changed. Description was OK. The line from the Change Proposal was not added because of the assessment made by the Semantic Task Force on CP-18
Assignment 2019-11-12 08:13:04 : Assigned To Mathias Ghys by Mathias Ghys
Tracking / Status = Open 2019-11-12 08:13:03 : Tracking by Mathias Ghys
Description
Finding:

- As an outcome of CP-18, the description of the hl7:id element has to be replaced with:

“Prescription ID. The following must be true:

- The prescription ID must be globally unique.

- The prescription ID must be the same as the prescription ID defined in the document header (document ID).

- The prescription ID can be used by the prescribing system or provider to identify the prescription to which it belongs. This provides the link from the dispensed medicine to the prescription.”

Suggestion:

-

Further explanation:

- Link to JIRA issue: https://ec.europa.eu/cefdigital/tracker/browse/EHSEMANTIC-509

Change Request Status = Closed ( epsos-issue-328 ): Frequency of intakes not bound to the epSOSTimingEvent value set in the case of the EIVL_TS datatype
Type Change Request Status Change Request Status = Closed Priority Normal
Events
Tracking / Status = Closed 2019-12-23 09:24:25 : Tracking by Mathias Ghys
Description
Implemented
Assignment 2019-12-23 09:23:32 : Assigned To Mathias Ghys by Mathias Ghys
Tracking / Status = Open 2019-12-23 09:23:31 : Tracking by Mathias Ghys
Description
Finding:

- At the moment, in the SubstanceAdministration template (https://art-decor.ehdsi.eu/art-decor/decor-templates--epsos-?id=1.3.6.1.4.1.12559.11.10.1.3.1.3.2) the use of the different possible data types:

  • TS
  • PIVL_TS
  • EIVL_TS
  • SXPR_TS

is explained in the description. But there are no bindings provided to the dedicated value set (epSOSTimingEvent) in the case of the EIVL_TS datatype.

Suggestion:

- It might be a good idea to align it with the format used by the IPS: http://international-patient-summary.net/mediawiki/index.php?title=2.16.840.1.113883.10.21.4.6

Further explanation:

- Approved during the semantic STF Arch WG meeting from 4/12/2019: https://ec.europa.eu/cefdigital/wiki/x/9gEpCg
Link to related JIRA issue: https://ec.europa.eu/cefdigital/tracker/browse/EHSEMANTIC-433

 
 
Busy
Structure Definitions (External repositories)