eHDSI Substance Administration
Issues (1)
Change Request Status = Closed (epsos-issue-393): Schematron validation error for doseQuantity element
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Events
Tracking / Status = Closed 2023-01-18 14:47:04: Tracking by Mathias Ghys
Assignment2023-01-18 14:36:06: Assigned To Mathias Ghys by Mathias Ghys
Tracking / Status = Open 2023-01-18 14:36:05: Tracking by Mathias Ghys
Description
Finding:

It was reported to us by PL, that strange Schematron errors were thrown for the doseQuantity low and high elements:

Most probably this is related with the IVXB_TS datatype of the hl7:low and hl7:high subelements.

This is causing just issues for the Schematron validation, and it can be seen in following evidence: https://gazelle.ehdsi.eu/EVSClient/detailedResult.seam?type=CDA&oid=1.3.6.1.4.1.12559.11.30.2.1.176383

Suggestion:

The datatype of the low and high subelements must be changed from IVXB_TS to IVXB_PQ.