Issues (4)
Change Request Status = Closed (epsos-issue-401): Rework the doseQuantity definition
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Events
Tracking / Status = Closed 2023-05-03 16:26:58: Tracking by Mathias Ghys
Assignment2023-05-03 15:56:24: Assigned To Mathias Ghys by Mathias Ghys
Tracking / Status = Open 2023-05-03 15:56:23: Tracking by Mathias Ghys
Description
Finding:

In the current CDA IGs, the doseQuantity requires both the low and high subelements to be present.

When the doseQuantity is no range, the low and the high contain the same value, which might be confusing. It should also be possible to define the doseQuantity as:

<doseQuantity value="1" unit="{tablet}"/>

First it needs to be presented and agreed in the STF Arch WG

Link to JIRA issue: https://citnet.tech.ec.europa.eu/CITnet/jira/browse/EHEALTH-9648

Suggestion:

-

Further explanation:

-

Change Request Status = Closed (epsos-issue-403): Add @inversionInd to entryRelationship structure for substitution
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Events
Tracking / Status = Closed 2023-05-03 16:27:53: Tracking by Mathias Ghys
Assignment2023-05-03 15:59:02: Assigned To Mathias Ghys by Mathias Ghys
Tracking / Status = Open 2023-05-03 15:59:01: Tracking by Mathias Ghys
Description
Finding:

- This issue was reported by Spain:

After reviewing Wave 6 ePrescription DisplayTool (v6.2.0) regarding substitution, a small discrepancy between Art-Decor and the CDA Display Tool was found.

In DisplayTool, it is being checked that it is always coming “inversionInd=true” (epPrescriptionItem.xsl):

However, in ArtDecor 6.5.0 (https://art-decor.ehdsi.eu/publication/epSOS/epsos-html-20230118T153212/tmp-1.3.6.1.4.1.12559.11.10.1.3.1.3.2-2022-12-13T144456.html) this property is missing:

The CDA IGs need to be modified to add this attribute as a fixed one.

JIRA Link: https://citnet.tech.ec.europa.eu/CITnet/jira/browse/EHEALTH-9744

Suggestion:

-

Further explanation:

-

Change Request Status = Closed (epsos-issue-406): Inconsistency with substitution description
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Events
Tracking / Status = Closed 2023-05-03 16:31:11: Tracking by Mathias Ghys
Assignment2023-05-03 16:02:28: Assigned To Mathias Ghys by Mathias Ghys
Tracking / Status = Open 2023-05-03 16:02:27: Tracking by Mathias Ghys
Description
Finding:

The substitution logic description is not aligned with the implementation:

https://art-decor.ehdsi.eu/html/publication/epSOS/epsos-html-20230118T153212/tmp-1.3.6.1.4.1.12559.11.10.1.3.1.3.2-2022-12-13T144456.html

This text:
Within the epSOS-I scope the “N” code shall be interpreted as No substitution allowed excepting for the Package Size.

The presence of any other code that is not “N”, or the absence of the substitution instructions, means that also the brand name (as well as the Package Size) can be changed.

The implemented logic is:
Substitution No -> only brand name can be modified.
Substitution Yes -> brand name, package size and number of packages can be modified.

This must be reflected in the description.

Suggestion by the eP Cluster:

Therefore we suggest a new phrasing: 
  • When substitution is not allowed: The same medicinal product must be dispensed, the product name may differ when a product is marketed under different names in different countries.
  • When substitution is allowed: The product name can differ as generic substitution allows products from other manufacturers to be dispensed.
Link to JIRA issue: https://citnet.tech.ec.europa.eu/CITnet/jira/browse/EHEALTH-9775

Suggestion:

-

Further explanation:

-

Change Request Status = Closed (epsos-issue-412): Inconsistent description for number of packages
TypeChange RequestStatusChange Request Status = Closed PriorityNormal
Events
Tracking / Status = Closed 2023-05-03 16:35:49: Tracking by Mathias Ghys
Assignment2023-05-03 16:18:38: Assigned To Mathias Ghys by Mathias Ghys
Tracking / Status = Open 2023-05-03 16:18:37: Tracking by Mathias Ghys
Description
Finding:

- Issue raised by LV:

Hey again, one more potential issue we found:

This comment seems to be inaccurate, because the eDispensation guidelines don't contain this block:

https://art-decor.ehdsi.eu/html/publication/epSOS/epsos-html-20230118T153212/tmp-1.3.6.1.4.1.12559.11.10.1.3.1.3.2-2022-12-13T144456.html 

eD guidelines:

https://art-decor.ehdsi.eu/html/publication/epSOS/epsos-html-20230118T153212/tmp-2.16.840.1.113883.3.1937.777.11.10.144-2022-09-14T131818.html

Link to JIRA issue: https://citnet.tech.ec.europa.eu/CITnet/jira/browse/EHEALTH-9958

Suggestion:

-

Further explanation:

-

 
 